Al-Noor Textile Mills

100.0 kW Hybrid system in Islamabad, commissioned 11 Jun 2020

System health

67

Performance ratio against baseline, less open defects

Generated (30 days)

9.8 MWh

87% of expected

Modelled soiling loss

15.2%

Last cleaned 16 May 2026

Performance ratio

70.5%

Baseline 81%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
100.0 kW
System type
Hybrid
Modules
183 x 545W Canadian Solar
Inverter
Solis S6-GR1P-100K (90.0 kW)
Battery
20 kWh
Tilt / azimuth
13 deg / 185 deg
Bird mesh
Not installed
Tariff
Rs 44 per kWh
Net metering
Approved
NM reference
NM-2023-47204
Sanctioned
100 kW
AMC
Commercial Pro
Open findings

Unresolved defects on this site.

  • Heavy soiling on lower rows

    Minor

    Dust accumulation reducing output on the two lowest rows more than the rest of the array.

  • Inverter derating in afternoon peak

    Major

    Unit throttles above 46 degrees ambient. Cooling fins clogged with dust.

  • Hotspot detected on string B

    Critical

    Thermal scan shows a cell running 27 degrees above array average. Bypass diode failure suspected.

Work order history

8 visits

CodeServiceStatusAmount
JOB-2026-0033Bird Dropping RemovalScheduledRs 3.5K
JOB-2026-0073Solar Panels with UPS ConnectionRequestedRs 14.5K
JOB-2026-0114IV Curve TestingCompletedRs 85.0K
JOB-2026-0030MC4 Connector ReplacementCompletedRs 2.5K
JOB-2026-0034Drone Solar InspectionInvoicedRs 90.0K
JOB-2026-0168Solar System Routine CheckingInvoicedRs 5.5K
JOB-2026-0091Smart Energy Monitoring App SetupCompletedRs 6.5K
JOB-2026-0028Performance OptimizationCompletedRs 95.0K