Operations console
All work orders
MC4 Connector Replacement
JOB-2026-0030 - raised via AMC schedule 2 mo ago
CompletedNormal priorityCommercial Pro AMC
Checklist
6 of 6 steps complete
Findings
Defects recorded on site. Unresolved criticals roll up to the operations overview.
Inverter derating in afternoon peak
MajorUnit throttles above 46 degrees ambient. Cooling fins clogged with dust.
Open
Monitoring app not configured
InfoCustomer has no visibility of live generation. App setup offered.
Resolved
Parts used
Consumed from van stock on this visit.
| Part | Qty | Unit cost | Line total |
|---|---|---|---|
| Torque Wrench Calibration | 1 | Rs 9,741 | Rs 9,741 |
| MC4 Connector Pair | 1 | Rs 19,134 | Rs 19,134 |
Result
Generation either side of the visit.
+14 kWhper day
277 kWh before, 291 kWh after
Worth about Rs 18,480 a month at this site's tariff.
Assignment
Technician
Shoaib AkhtarDetails
- Customer
- Al-Noor Textile Mills
- City
- Islamabad
- Capacity
- 100.0 kW
- Raised
- 9 Jun 2026, 3:00 PM
- Scheduled
- 9 Jun 2026, 8:00 PM
- SLA due
- 9 Jun 2026, 11:00 PM (2 mo ago)
- Completed
- 9 Jun 2026, 8:00 PM
- Services
- MC4 Connector Replacement
- Amount
- Rs 2,550