Operations console
Nadia Rehman
10.0 kW Off-Grid system in Faisalabad, commissioned 10 Mar 2025
System health
73
Performance ratio against baseline, less open defects
Generated (30 days)
966 kWh
85% of expected
Modelled soiling loss
6.7%
Last cleaned 1 Jun 2026
Performance ratio
70.2%
Baseline 83%, target 82%
Ninety days. The dashed line is the design expectation; the gap between the lines is money.
Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.
Against the fleet target.
- Capacity
- 10.0 kW
- System type
- Off-Grid
- Modules
- 17 x 585W Canadian Solar
- Inverter
- Fronius Primo-10K (9.0 kW)
- Battery
- 5 kWh
- Tilt / azimuth
- 16 deg / 190 deg
- Bird mesh
- Installed
- Tariff
- Rs 53 per kWh
- Net metering
- Not applied
- NM reference
- -
- Sanctioned
- -
- AMC
- Quarterly Care
Unresolved defects on this site.
Hotspot detected on string B
CriticalThermal scan shows a cell running 27 degrees above array average. Bypass diode failure suspected.
7 visits
| Code | Service | Status | Amount |
|---|---|---|---|
| JOB-2026-0071 | On-Grid Solar System | In progress | Rs 27 |
| JOB-2026-0075 | Off-Grid Solar System | In progress | Rs 34 |
| JOB-2026-0027 | Lightning Protection | Completed | Rs 18.0K |
| JOB-2026-0126 | Residential Solar Maintenance | Invoiced | Rs 6.5K |
| JOB-2026-0082 | Junction Box Repair | Cancelled | Rs 4.5K |
| JOB-2026-0160 | Cable Replacement | Invoiced | Rs 7.7K |
| JOB-2026-0018 | Bird Dropping Removal | Completed | Rs 3.5K |
- Insulation Resistance TestingScore 76
11 Feb 2026
- String TestingScore 65
6 Mar 2026
Generation figures are modelled against the design estimate for this system.