Operations console

Customers

Nadia Rehman

10.0 kW Off-Grid system in Faisalabad, commissioned 10 Mar 2025

System health

73

Performance ratio against baseline, less open defects

Generated (30 days)

966 kWh

85% of expected

Modelled soiling loss

6.7%

Last cleaned 1 Jun 2026

Performance ratio

70.2%

Baseline 83%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
10.0 kW
System type
Off-Grid
Modules
17 x 585W Canadian Solar
Inverter
Fronius Primo-10K (9.0 kW)
Battery
5 kWh
Tilt / azimuth
16 deg / 190 deg
Bird mesh
Installed
Tariff
Rs 53 per kWh
Net metering
Not applied
NM reference
-
Sanctioned
-
AMC
Quarterly Care
Open findings

Unresolved defects on this site.

  • Hotspot detected on string B

    Critical

    Thermal scan shows a cell running 27 degrees above array average. Bypass diode failure suspected.

Work order history

7 visits

CodeServiceStatusAmount
JOB-2026-0071On-Grid Solar SystemIn progressRs 27
JOB-2026-0075Off-Grid Solar SystemIn progressRs 34
JOB-2026-0027Lightning ProtectionCompletedRs 18.0K
JOB-2026-0126Residential Solar MaintenanceInvoicedRs 6.5K
JOB-2026-0082Junction Box RepairCancelledRs 4.5K
JOB-2026-0160Cable ReplacementInvoicedRs 7.7K
JOB-2026-0018Bird Dropping RemovalCompletedRs 3.5K
Inspection reports