Operations console

All reports

Insulation Resistance Testing

RPT-2026-014 - performed 11 Feb 2026 by Danish Ali

Health score

76

Measurements taken

6

1 outside reference

Findings

2

Customer visibility

Shared

Measurements

Each reading against the reference it is judged by.

MeasurementReadingReferenceResult
Open circuit voltage (string A)626 VWithin 5% of designPass
Short circuit current (string A)9.9 AWithin 8% of nameplatePass
Earth electrode resistance7.5 ohmBelow 5 ohmPass
Insulation resistance (DC+ to earth)82 MohmAbove 1 MohmOutside reference
Max module temperature50 CBelow 25 C above ambientPass
Performance ratio on test day68%Baseline 83%Pass
Context
Customer
Nadia Rehman
Capacity
10.0 kW
Work order
JOB-2026-0018
Technician
Danish Ali
Recommendation

Bring cleaning forward by one cycle and re-torque the affected strings within 30 days.

Score 76 / 100
Findings

Defects recorded during this inspection.

  • Loose structure bolt

    MinorResolved

    Two mid-clamps below torque specification on the north row. Retorqued.

  • String mismatch on MPPT 2

    MajorResolved

    String currents differ by 18 percent, pointing to partial shading or module degradation.