Rehmat Flour Mills - Unit 1

25.0 kW Hybrid system in Karachi, commissioned 6 Aug 2024

System health

76

Performance ratio against baseline, less open defects

Generated (30 days)

2.5 MWh

90% of expected

Modelled soiling loss

13.8%

Last cleaned 12 Apr 2026

Performance ratio

72.8%

Baseline 81%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
25.0 kW
System type
Hybrid
Modules
46 x 545W Jinko
Inverter
GoodWe DNS-G3-25K (22.5 kW)
Battery
5 kWh
Tilt / azimuth
16 deg / 170 deg
Bird mesh
Not installed
Tariff
Rs 49 per kWh
Net metering
Approved
NM reference
NM-2023-66615
Sanctioned
25 kW
AMC
Annual Plus
Open findings

Unresolved defects on this site.

  • Hotspot detected on string B

    Critical

    Thermal scan shows a cell running 27 degrees above array average. Bypass diode failure suspected.

  • Bird nesting under array

    Minor

    Pigeons nesting between modules and roof. Bird mesh recommended for the full perimeter.

Work order history

4 visits

CodeServiceStatusAmount
JOB-2026-0127Commercial Solar InstallationScheduledRs 26
JOB-2026-0002Insurance InspectionCompletedRs 9.5K
JOB-2026-0036Waterless Panel CleaningInvoicedRs 12.0K
JOB-2026-0072MC4 Connector ReplacementInvoicedRs 850
Inspection reports

Generation figures are modelled against the design estimate for this system.