Sunrise Poultry Farm
25.0 kW On-Grid system in Multan, commissioned 24 Sep 2022
System health
74
Performance ratio against baseline, less open defects
Generated (30 days)
2.4 MWh
84% of expected
Modelled soiling loss
17.1%
Last cleaned 30 May 2026
Performance ratio
72.4%
Baseline 86%, target 82%
Ninety days. The dashed line is the design expectation; the gap between the lines is money.
Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.
Against the fleet target.
- Capacity
- 25.0 kW
- System type
- On-Grid
- Modules
- 40 x 620W Longi
- Inverter
- Huawei SUN2000-25K (22.5 kW)
- Battery
- None
- Tilt / azimuth
- 20 deg / 190 deg
- Bird mesh
- Installed
- Tariff
- Rs 46 per kWh
- Net metering
- Approved
- NM reference
- NM-2025-71251
- Sanctioned
- 25 kW
- AMC
- Annual Plus
Unresolved defects on this site.
Warranty documents missing
InfoModule warranty pack not on file. Copies requested from the original installer.
String mismatch on MPPT 2
MajorString currents differ by 18 percent, pointing to partial shading or module degradation.
Loose structure bolt
MinorTwo mid-clamps below torque specification on the north row. Retorqued.
8 visits
| Code | Service | Status | Amount |
|---|---|---|---|
| JOB-2026-0054 | Waterless Panel Cleaning | In progress | Rs 10.4K |
| JOB-2026-0117 | Panel Angle Optimization | Scheduled | Rs 5.8K |
| JOB-2026-0157 | Inverter Repair & Maintenance | Scheduled | Rs 14.5K |
| JOB-2026-0088 | Bird Dropping Removal | Completed | Rs 3.5K |
| JOB-2026-0076 | Solar Panels with UPS Connection | Completed | Rs 14.5K |
| JOB-2026-0096 | String Testing | Invoiced | Rs 6.8K |
| JOB-2026-0026 | Fuse Replacement | Completed | Rs 1.9K |
| JOB-2026-0134 | Complete Inspection & Checkup | Completed | Rs 7.5K |
- IV Curve TestingScore 58
27 Mar 2026
- IV Curve TestingScore 68
9 Feb 2026
Generation figures are modelled against the design estimate for this system.