Findings

Defects recorded on site. Unresolved criticals roll up to the operations overview.

  • Inverter derating in afternoon peak

    Major

    Unit throttles above 46 degrees ambient. Cooling fins clogged with dust.

    Resolved

Parts used

Consumed from van stock on this visit.

PartQtyUnit costLine total
Cable Tie UV 300mm3Rs 13,502Rs 40,506
Torque Wrench Calibration3Rs 9,741Rs 29,223
Result

Generation either side of the visit.

+6 kWhper day

75 kWh before, 81 kWh after

Worth about Rs 8,280 a month at this site's tariff.