Operations console

All reports

IV Curve Testing

RPT-2026-011 - performed 27 Mar 2026 by Naveed Iqbal

Health score

58

Measurements taken

6

2 outside reference

Findings

2

Customer visibility

Shared

Measurements

Each reading against the reference it is judged by.

MeasurementReadingReferenceResult
Open circuit voltage (string A)627 VWithin 5% of designPass
Short circuit current (string A)10.6 AWithin 8% of nameplatePass
Earth electrode resistance6.1 ohmBelow 5 ohmPass
Insulation resistance (DC+ to earth)5 MohmAbove 1 MohmPass
Max module temperature65 CBelow 25 C above ambientOutside reference
Performance ratio on test day62%Baseline 86%Outside reference
Context
Capacity
25.0 kW
Work order
JOB-2026-0096
Technician
Naveed Iqbal
Recommendation

Schedule corrective repair within 14 days. Losses at the current rate exceed the cost of the fix.

Score 58 / 100
Findings

Defects recorded during this inspection.

  • Warranty documents missing

    InfoOpen

    Module warranty pack not on file. Copies requested from the original installer.

  • String mismatch on MPPT 2

    MajorOpen

    String currents differ by 18 percent, pointing to partial shading or module degradation.