Crescent Plaza - Unit 1

32.0 kW Hybrid system in Faisalabad, commissioned 24 May 2021

System health

74

Performance ratio against baseline, less open defects

Generated (30 days)

3.2 MWh

88% of expected

Modelled soiling loss

12.8%

Last cleaned 24 Jun 2026

Performance ratio

73.3%

Baseline 83%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
32.0 kW
System type
Hybrid
Modules
55 x 585W Longi
Inverter
GoodWe DNS-G3-32K (28.8 kW)
Battery
20 kWh
Tilt / azimuth
12 deg / 200 deg
Bird mesh
Installed
Tariff
Rs 44 per kWh
Net metering
In process
NM reference
NM-2025-88946
Sanctioned
32 kW
AMC
Annual Plus
Open findings

Unresolved defects on this site.

  • Monitoring app not configured

    Info

    Customer has no visibility of live generation. App setup offered.

  • Hotspot detected on string B

    Critical

    Thermal scan shows a cell running 27 degrees above array average. Bypass diode failure suspected.

Work order history

4 visits

CodeServiceStatusAmount
JOB-2026-0064Electrical Safety AuditDispatchedRs 15.0K
JOB-2026-0077Warranty ClaimsCompletedRs 4.5K
JOB-2026-0062Farm Solar MaintenanceCompletedRs 21.0K
JOB-2026-0021Emergency Breakdown ServiceCompletedRs 12.5K
Inspection reports

Generation figures are modelled against the design estimate for this system.