Operations console
Rabia Nawaz
12.0 kW On-Grid system in Rawalpindi, commissioned 7 Jul 2023
System health
83
Performance ratio against baseline, less open defects
Generated (30 days)
1.1 MWh
84% of expected
Modelled soiling loss
15.5%
Last cleaned 30 Apr 2026
Performance ratio
69.2%
Baseline 82%, target 82%
Ninety days. The dashed line is the design expectation; the gap between the lines is money.
Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.
Against the fleet target.
- Capacity
- 12.0 kW
- System type
- On-Grid
- Modules
- 21 x 585W Longi
- Inverter
- Growatt MIN-TL-X-12K (10.8 kW)
- Battery
- None
- Tilt / azimuth
- 16 deg / 180 deg
- Bird mesh
- Installed
- Tariff
- Rs 61 per kWh
- Net metering
- Not applied
- NM reference
- -
- Sanctioned
- -
- AMC
- Quarterly Care
Unresolved defects on this site.
Warranty documents missing
InfoModule warranty pack not on file. Copies requested from the original installer.
3 visits
| Code | Service | Status | Amount |
|---|---|---|---|
| JOB-2026-0093 | Free Site Survey | Invoiced | Rs 0 |
| JOB-2026-0105 | Battery Check & Replacement | Completed | Rs 19.0K |
| JOB-2026-0044 | Solar System Routine Checking | Completed | Rs 5.5K |
- Thermal Camera InspectionScore 78
19 May 2026
- System Health AuditScore 78
3 Mar 2026
Generation figures are modelled against the design estimate for this system.