Operations console

All work orders

Solar System Routine Checking

JOB-2026-0044 - raised via AMC schedule 6 mo ago

CompletedNormal priorityQuarterly Care AMC
Checklist

6 of 6 steps complete

Findings

Defects recorded on site. Unresolved criticals roll up to the operations overview.

  • Inverter derating in afternoon peak

    Major

    Unit throttles above 46 degrees ambient. Cooling fins clogged with dust.

    Resolved

  • Warranty documents missing

    Info

    Module warranty pack not on file. Copies requested from the original installer.

    Open

  • Earthing resistance above limit

    Major

    Measured 9.4 ohm against a 5 ohm reference. Earth pit needs re-treatment.

    Resolved

Parts used

Consumed from van stock on this visit.

PartQtyUnit costLine total
Safety Harness4Rs 6,849Rs 27,396
Lithium Battery 5kWh3Rs 40,505Rs 121,515
Result

Generation either side of the visit.

+5 kWhper day

37 kWh before, 42 kWh after

Worth about Rs 9,150 a month at this site's tariff.

Assignment

Technician

Faisal Shahzad
Details
Customer
Rabia Nawaz
City
Rawalpindi
Capacity
12.0 kW
Raised
3 Mar 2026, 12:00 PM
Scheduled
3 Mar 2026, 9:00 PM
SLA due
5 Mar 2026, 12:00 PM (6 mo ago)
Completed
3 Mar 2026, 9:00 PM
Services
Solar System Routine Checking
Amount
Rs 5,500