Operations console

All reports

Thermal Camera Inspection

RPT-2026-018 - performed 19 May 2026 by Faisal Shahzad

Health score

78

Measurements taken

6

1 outside reference

Findings

1

Customer visibility

Internal only

Measurements

Each reading against the reference it is judged by.

MeasurementReadingReferenceResult
Open circuit voltage (string A)678 VWithin 5% of designPass
Short circuit current (string A)10 AWithin 8% of nameplatePass
Earth electrode resistance5.3 ohmBelow 5 ohmPass
Insulation resistance (DC+ to earth)24 MohmAbove 1 MohmPass
Max module temperature54 CBelow 25 C above ambientOutside reference
Performance ratio on test day84%Baseline 82%Pass
Context
Customer
Rabia Nawaz
Capacity
12.0 kW
Work order
JOB-2026-0105
Technician
Faisal Shahzad
Recommendation

Bring cleaning forward by one cycle and re-torque the affected strings within 30 days.

Score 78 / 100
Findings

Defects recorded during this inspection.

  • Heavy soiling on lower rows

    MinorResolved

    Dust accumulation reducing output on the two lowest rows more than the rest of the array.