Operations console
Imran Baig
5.0 kW Off-Grid system in Multan, commissioned 22 May 2025
System health
75
Performance ratio against baseline, less open defects
Generated (30 days)
505 kWh
89% of expected
Modelled soiling loss
13.8%
Last cleaned 16 Jul 2026
Performance ratio
70.3%
Baseline 79%, target 82%
Ninety days. The dashed line is the design expectation; the gap between the lines is money.
Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.
Against the fleet target.
- Capacity
- 5.0 kW
- System type
- Off-Grid
- Modules
- 8 x 620W Jinko
- Inverter
- Huawei SUN2000-5K (4.5 kW)
- Battery
- 5 kWh
- Tilt / azimuth
- 22 deg / 190 deg
- Bird mesh
- Not installed
- Tariff
- Rs 52 per kWh
- Net metering
- Not applied
- NM reference
- -
- Sanctioned
- -
- AMC
- Quarterly Care
Unresolved defects on this site.
String mismatch on MPPT 2
MajorString currents differ by 18 percent, pointing to partial shading or module degradation.
Monitoring app not configured
InfoCustomer has no visibility of live generation. App setup offered.
Earthing resistance above limit
MajorMeasured 9.4 ohm against a 5 ohm reference. Earth pit needs re-treatment.
7 visits
| Code | Service | Status | Amount |
|---|---|---|---|
| JOB-2026-0065 | Performance Testing | Requested | Rs 9.0K |
| JOB-2026-0001 | Commercial Solar Maintenance | Invoiced | Rs 18.0K |
| JOB-2026-0022 | Annual Maintenance Contract (AMC) | Completed | Rs 48.0K |
| JOB-2026-0163 | Complete Inspection & Checkup | Cancelled | Rs 7.5K |
| JOB-2026-0005 | Same-Day Repair | Completed | Rs 16.5K |
| JOB-2026-0107 | Wiring Inspection & Repair | Invoiced | Rs 8.2K |
| JOB-2026-0025 | Commercial Solar Maintenance | Invoiced | Rs 18.0K |
- System Health AuditScore 60
14 Feb 2026
Generation figures are modelled against the design estimate for this system.