Operations console

Customers

Imran Baig

5.0 kW Off-Grid system in Multan, commissioned 22 May 2025

System health

75

Performance ratio against baseline, less open defects

Generated (30 days)

505 kWh

89% of expected

Modelled soiling loss

13.8%

Last cleaned 16 Jul 2026

Performance ratio

70.3%

Baseline 79%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
5.0 kW
System type
Off-Grid
Modules
8 x 620W Jinko
Inverter
Huawei SUN2000-5K (4.5 kW)
Battery
5 kWh
Tilt / azimuth
22 deg / 190 deg
Bird mesh
Not installed
Tariff
Rs 52 per kWh
Net metering
Not applied
NM reference
-
Sanctioned
-
AMC
Quarterly Care
Open findings

Unresolved defects on this site.

  • String mismatch on MPPT 2

    Major

    String currents differ by 18 percent, pointing to partial shading or module degradation.

  • Monitoring app not configured

    Info

    Customer has no visibility of live generation. App setup offered.

  • Earthing resistance above limit

    Major

    Measured 9.4 ohm against a 5 ohm reference. Earth pit needs re-treatment.

Work order history

7 visits

CodeServiceStatusAmount
JOB-2026-0065Performance TestingRequestedRs 9.0K
JOB-2026-0001Commercial Solar MaintenanceInvoicedRs 18.0K
JOB-2026-0022Annual Maintenance Contract (AMC)CompletedRs 48.0K
JOB-2026-0163Complete Inspection & CheckupCancelledRs 7.5K
JOB-2026-0005Same-Day RepairCompletedRs 16.5K
JOB-2026-0107Wiring Inspection & RepairInvoicedRs 8.2K
JOB-2026-0025Commercial Solar MaintenanceInvoicedRs 18.0K
Inspection reports

Generation figures are modelled against the design estimate for this system.