Findings

Defects recorded on site. Unresolved criticals roll up to the operations overview.

  • Earthing resistance above limit

    Major

    Measured 9.4 ohm against a 5 ohm reference. Earth pit needs re-treatment.

    Open

  • Inverter derating in afternoon peak

    Major

    Unit throttles above 46 degrees ambient. Cooling fins clogged with dust.

    Resolved

Parts used

Consumed from van stock on this visit.

No parts consumed

Result

Generation either side of the visit.

+1 kWhper day

15 kWh before, 16 kWh after

Worth about Rs 1,560 a month at this site's tariff.