Operations console

Customers

Ayesha Malik

12.0 kW On-Grid system in Faisalabad, commissioned 4 Oct 2021

System health

74

Performance ratio against baseline, less open defects

Generated (30 days)

1.2 MWh

92% of expected

Modelled soiling loss

10.3%

Last cleaned 30 Apr 2026

Performance ratio

76.3%

Baseline 83%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
12.0 kW
System type
On-Grid
Modules
22 x 555W JA Solar
Inverter
GoodWe DNS-G3-12K (10.8 kW)
Battery
None
Tilt / azimuth
29 deg / 180 deg
Bird mesh
Not installed
Tariff
Rs 51 per kWh
Net metering
Approved
NM reference
NM-2023-70292
Sanctioned
12 kW
AMC
No contract
Open findings

Unresolved defects on this site.

  • Earthing resistance above limit

    Major

    Measured 9.4 ohm against a 5 ohm reference. Earth pit needs re-treatment.

  • Hotspot detected on string B

    Critical

    Thermal scan shows a cell running 27 degrees above array average. Bypass diode failure suspected.

Work order history

12 visits

CodeServiceStatusAmount
JOB-2026-0138Solar Relocation (Shifting)ScheduledRs 86.4K
JOB-2026-0146Energy Loss AnalysisIn progressRs 11.0K
JOB-2026-0003Solar Relocation (Shifting)InvoicedRs 86.4K
JOB-2026-0087Free Performance ReportCompletedRs 0
JOB-2026-0142Panel Angle OptimizationRequestedRs 5.8K
JOB-2026-0081Fire Safety InspectionIn progressRs 7.5K
JOB-2026-0112Solar System Routine CheckingScheduledRs 5.5K
JOB-2026-0019On-Grid Solar SystemCompletedRs 27
JOB-2026-0083Bird Dropping RemovalInvoicedRs 3.5K
JOB-2026-0047Solar Relocation (Shifting)CancelledRs 86.4K
JOB-2026-0133Bird Mesh InstallationCompletedRs 31.2K
JOB-2026-0031Hotspot DetectionInvoicedRs 7.8K
Inspection reports

No reports for this site

Generation figures are modelled against the design estimate for this system.