Operations console
Ayesha Malik
12.0 kW On-Grid system in Faisalabad, commissioned 4 Oct 2021
System health
74
Performance ratio against baseline, less open defects
Generated (30 days)
1.2 MWh
92% of expected
Modelled soiling loss
10.3%
Last cleaned 30 Apr 2026
Performance ratio
76.3%
Baseline 83%, target 82%
Ninety days. The dashed line is the design expectation; the gap between the lines is money.
Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.
Against the fleet target.
- Capacity
- 12.0 kW
- System type
- On-Grid
- Modules
- 22 x 555W JA Solar
- Inverter
- GoodWe DNS-G3-12K (10.8 kW)
- Battery
- None
- Tilt / azimuth
- 29 deg / 180 deg
- Bird mesh
- Not installed
- Tariff
- Rs 51 per kWh
- Net metering
- Approved
- NM reference
- NM-2023-70292
- Sanctioned
- 12 kW
- AMC
- No contract
Unresolved defects on this site.
Earthing resistance above limit
MajorMeasured 9.4 ohm against a 5 ohm reference. Earth pit needs re-treatment.
Hotspot detected on string B
CriticalThermal scan shows a cell running 27 degrees above array average. Bypass diode failure suspected.
12 visits
| Code | Service | Status | Amount |
|---|---|---|---|
| JOB-2026-0138 | Solar Relocation (Shifting) | Scheduled | Rs 86.4K |
| JOB-2026-0146 | Energy Loss Analysis | In progress | Rs 11.0K |
| JOB-2026-0003 | Solar Relocation (Shifting) | Invoiced | Rs 86.4K |
| JOB-2026-0087 | Free Performance Report | Completed | Rs 0 |
| JOB-2026-0142 | Panel Angle Optimization | Requested | Rs 5.8K |
| JOB-2026-0081 | Fire Safety Inspection | In progress | Rs 7.5K |
| JOB-2026-0112 | Solar System Routine Checking | Scheduled | Rs 5.5K |
| JOB-2026-0019 | On-Grid Solar System | Completed | Rs 27 |
| JOB-2026-0083 | Bird Dropping Removal | Invoiced | Rs 3.5K |
| JOB-2026-0047 | Solar Relocation (Shifting) | Cancelled | Rs 86.4K |
| JOB-2026-0133 | Bird Mesh Installation | Completed | Rs 31.2K |
| JOB-2026-0031 | Hotspot Detection | Invoiced | Rs 7.8K |
No reports for this site
Generation figures are modelled against the design estimate for this system.