Operations console

All reports

Thermal Camera Inspection

RPT-2026-010 - performed 19 Jun 2026 by Shoaib Akhtar

Health score

85

Measurements taken

6

1 outside reference

Findings

1

Customer visibility

Shared

Measurements

Each reading against the reference it is judged by.

MeasurementReadingReferenceResult
Open circuit voltage (string A)588 VWithin 5% of designPass
Short circuit current (string A)11.3 AWithin 8% of nameplatePass
Earth electrode resistance7.8 ohmBelow 5 ohmPass
Insulation resistance (DC+ to earth)83 MohmAbove 1 MohmOutside reference
Max module temperature48 CBelow 25 C above ambientPass
Performance ratio on test day65%Baseline 83%Pass
Context
Capacity
150.0 kW
Work order
JOB-2026-0147
Technician
Shoaib Akhtar
Recommendation

Bring cleaning forward by one cycle and re-torque the affected strings within 30 days.

Score 85 / 100
Findings

Defects recorded during this inspection.

  • Earthing resistance above limit

    MajorResolved

    Measured 9.4 ohm against a 5 ohm reference. Earth pit needs re-treatment.