Operations console
All reports
Thermal Camera Inspection
RPT-2026-010 - performed 19 Jun 2026 by Shoaib Akhtar
Health score
85
Measurements taken
6
1 outside reference
Findings
1
Customer visibility
Shared
Measurements
Each reading against the reference it is judged by.
| Measurement | Reading | Reference | Result |
|---|---|---|---|
| Open circuit voltage (string A) | 588 V | Within 5% of design | Pass |
| Short circuit current (string A) | 11.3 A | Within 8% of nameplate | Pass |
| Earth electrode resistance | 7.8 ohm | Below 5 ohm | Pass |
| Insulation resistance (DC+ to earth) | 83 Mohm | Above 1 Mohm | Outside reference |
| Max module temperature | 48 C | Below 25 C above ambient | Pass |
| Performance ratio on test day | 65% | Baseline 83% | Pass |
Context
- Customer
- Metro Warehousing
- Capacity
- 150.0 kW
- Work order
- JOB-2026-0147
- Technician
- Shoaib Akhtar
Recommendation
Bring cleaning forward by one cycle and re-torque the affected strings within 30 days.
Score 85 / 100Findings
Defects recorded during this inspection.
Earthing resistance above limit
MajorResolvedMeasured 9.4 ohm against a 5 ohm reference. Earth pit needs re-treatment.