Operations console

Customers

Falcon Logistics - Unit 1

32.0 kW On-Grid system in Lahore, commissioned 16 Oct 2025

System health

71

Performance ratio against baseline, less open defects

Generated (30 days)

3.3 MWh

91% of expected

Modelled soiling loss

6.7%

Last cleaned 10 Aug 2026

Performance ratio

75.2%

Baseline 83%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
32.0 kW
System type
On-Grid
Modules
55 x 585W Longi
Inverter
Solis S6-GR1P-32K (28.8 kW)
Battery
None
Tilt / azimuth
13 deg / 170 deg
Bird mesh
Installed
Tariff
Rs 46 per kWh
Net metering
Approved
NM reference
NM-2023-65503
Sanctioned
32 kW
AMC
Commercial Pro
Open findings

Unresolved defects on this site.

  • Heavy soiling on lower rows

    Minor

    Dust accumulation reducing output on the two lowest rows more than the rest of the array.

  • Inverter derating in afternoon peak

    Major

    Unit throttles above 46 degrees ambient. Cooling fins clogged with dust.

  • Burnt MC4 connector

    Critical

    DC connector on string C shows arcing damage. Replaced on site and adjacent connectors re-terminated.

Work order history

7 visits

CodeServiceStatusAmount
JOB-2026-0023Residential Solar MaintenanceRequestedRs 6.5K
JOB-2026-0170Combiner Box RepairRequestedRs 7.8K
JOB-2026-0167Factory Solar MaintenanceScheduledRs 32.0K
JOB-2026-0095Earthing Resistance TestingCompletedRs 5.2K
JOB-2026-0060Battery Check & ReplacementCompletedRs 38.0K
JOB-2026-0038MC4 Connector ReplacementCompletedRs 3.4K
JOB-2026-0057Annual Maintenance Contract (AMC)InvoicedRs 48.0K
Inspection reports

Generation figures are modelled against the design estimate for this system.