Operations console
Customers
Ahmed Raza
15.0 kW Off-Grid system in Lahore, commissioned 2 Aug 2024
System health
90
Performance ratio against baseline, less open defects
Generated (30 days)
1.5 MWh
90% of expected
Modelled soiling loss
8.2%
Last cleaned 22 Apr 2026
Performance ratio
74.8%
Baseline 83%, target 82%
Generation, expected against actual
Ninety days. The dashed line is the design expectation; the gap between the lines is money.
Soiling loss
Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.
Performance ratio trend
Against the fleet target.
System specification
- Capacity
- 15.0 kW
- System type
- Off-Grid
- Modules
- 27 x 555W Canadian Solar
- Inverter
- Huawei SUN2000-15K (13.5 kW)
- Battery
- 5 kWh
- Tilt / azimuth
- 29 deg / 200 deg
- Bird mesh
- Not installed
- Tariff
- Rs 48 per kWh
- Net metering
- Not applied
- NM reference
- -
- Sanctioned
- -
- AMC
- No contract
Open findings
Unresolved defects on this site.
No open findings
Work order history
4 visits
| Code | Service | Status | Amount |
|---|---|---|---|
| JOB-2026-0104 | System Health Audit | Dispatched | Rs 12.0K |
| JOB-2026-0098 | Earthing & Safety Inspection | In progress | Rs 6.2K |
| JOB-2026-0094 | Same-Day Repair | Cancelled | Rs 16.5K |
| JOB-2026-0101 | IV Curve Testing | Invoiced | Rs 12.8K |
Inspection reports
- Shade AnalysisScore 74
22 Feb 2026
Generation figures are modelled against the design estimate for this system.