Operations console
All reports
Shade Analysis
RPT-2026-023 - performed 22 Feb 2026 by Tahir Mahmood
Health score
74
Measurements taken
6
3 outside reference
Findings
1
Customer visibility
Shared
Measurements
Each reading against the reference it is judged by.
| Measurement | Reading | Reference | Result |
|---|---|---|---|
| Open circuit voltage (string A) | 697 V | Within 5% of design | Pass |
| Short circuit current (string A) | 10.8 A | Within 8% of nameplate | Pass |
| Earth electrode resistance | 2 ohm | Below 5 ohm | Outside reference |
| Insulation resistance (DC+ to earth) | 40 Mohm | Above 1 Mohm | Pass |
| Max module temperature | 55 C | Below 25 C above ambient | Outside reference |
| Performance ratio on test day | 83% | Baseline 83% | Outside reference |
Context
- Site
- Ahmed Raza
- Customer
- Ahmed Raza
- Capacity
- 15.0 kW
- Work order
- JOB-2026-0101
- Technician
- Tahir Mahmood
Recommendation
Bring cleaning forward by one cycle and re-torque the affected strings within 30 days.
Score 74 / 100Findings
Defects recorded during this inspection.
No defects found
InfoResolvedSystem operating within expected parameters on the day of inspection.