Operations console
All work orders
Performance Testing
JOB-2026-0165 - raised via Field survey 5 mo ago
InvoicedNormal priorityCommercial Pro AMC
Checklist
6 of 6 steps complete
Findings
Defects recorded on site. Unresolved criticals roll up to the operations overview.
Inverter derating in afternoon peak
MajorUnit throttles above 46 degrees ambient. Cooling fins clogged with dust.
Open
Warranty documents missing
InfoModule warranty pack not on file. Copies requested from the original installer.
Open
Parts used
Consumed from van stock on this visit.
| Part | Qty | Unit cost | Line total |
|---|---|---|---|
| DC Cable 4mm (per metre) | 4 | Rs 30,704 | Rs 122,816 |
| Module 585W Mono | 3 | Rs 10,786 | Rs 32,358 |
Result
Generation either side of the visit.
+26 kWhper day
92 kWh before, 118 kWh after
Worth about Rs 35,100 a month at this site's tariff.
Assignment
Technician
Waqar AhmedDetails
- Customer
- Pak Agro Farms
- City
- Karachi
- Capacity
- 25.0 kW
- Raised
- 28 Mar 2026, 11:00 AM
- Scheduled
- 28 Mar 2026, 3:00 PM
- SLA due
- 28 Mar 2026, 7:00 PM (5 mo ago)
- Completed
- 28 Mar 2026, 3:00 PM
- Services
- Performance Testing
- Amount
- Rs 9,000