Operations console

All reports

String Testing

RPT-2026-012 - performed 13 May 2026 by Naveed Iqbal

Health score

69

Measurements taken

6

1 outside reference

Findings

1

Customer visibility

Internal only

Measurements

Each reading against the reference it is judged by.

MeasurementReadingReferenceResult
Open circuit voltage (string A)737 VWithin 5% of designPass
Short circuit current (string A)12.3 AWithin 8% of nameplatePass
Earth electrode resistance2.4 ohmBelow 5 ohmPass
Insulation resistance (DC+ to earth)74 MohmAbove 1 MohmPass
Max module temperature65 CBelow 25 C above ambientPass
Performance ratio on test day65%Baseline 79%Outside reference
Context
Capacity
60.0 kW
Work order
JOB-2026-0012
Technician
Naveed Iqbal
Recommendation

Schedule corrective repair within 14 days. Losses at the current rate exceed the cost of the fix.

Score 69 / 100
Findings

Defects recorded during this inspection.

  • No defects found

    InfoResolved

    System operating within expected parameters on the day of inspection.