Operations console

All reports

Shade Analysis

RPT-2026-007 - performed 28 Feb 2026 by Waqar Ahmed

Health score

97

Measurements taken

6

1 outside reference

Findings

1

Customer visibility

Shared

Measurements

Each reading against the reference it is judged by.

MeasurementReadingReferenceResult
Open circuit voltage (string A)561 VWithin 5% of designPass
Short circuit current (string A)11.5 AWithin 8% of nameplatePass
Earth electrode resistance7.6 ohmBelow 5 ohmOutside reference
Insulation resistance (DC+ to earth)60 MohmAbove 1 MohmPass
Max module temperature75 CBelow 25 C above ambientPass
Performance ratio on test day70%Baseline 83%Pass
Context
Capacity
25.0 kW
Work order
JOB-2026-0137
Technician
Waqar Ahmed
Recommendation

System is healthy. Continue the current cleaning cycle and re-inspect in six months.

Score 97 / 100
Findings

Defects recorded during this inspection.

  • Heavy soiling on lower rows

    MinorOpen

    Dust accumulation reducing output on the two lowest rows more than the rest of the array.