Operations console

All reports

IV Curve Testing

RPT-2026-003 - performed 2 Jun 2026 by Faisal Shahzad

Health score

72

Measurements taken

6

2 outside reference

Findings

1

Customer visibility

Internal only

Measurements

Each reading against the reference it is judged by.

MeasurementReadingReferenceResult
Open circuit voltage (string A)746 VWithin 5% of designPass
Short circuit current (string A)9.8 AWithin 8% of nameplateOutside reference
Earth electrode resistance4.8 ohmBelow 5 ohmPass
Insulation resistance (DC+ to earth)24 MohmAbove 1 MohmPass
Max module temperature52 CBelow 25 C above ambientPass
Performance ratio on test day76%Baseline 79%Outside reference
Context
Capacity
200.0 kW
Work order
JOB-2026-0029
Technician
Faisal Shahzad
Recommendation

Bring cleaning forward by one cycle and re-torque the affected strings within 30 days.

Score 72 / 100
Findings

Defects recorded during this inspection.

  • No defects found

    InfoResolved

    System operating within expected parameters on the day of inspection.