Operations console

Customers

Gulberg Galleria

32.0 kW On-Grid system in Faisalabad, commissioned 19 Dec 2020

System health

75

Performance ratio against baseline, less open defects

Generated (30 days)

3.2 MWh

89% of expected

Modelled soiling loss

14.4%

Last cleaned 5 Jul 2026

Performance ratio

71.4%

Baseline 80%, target 82%

Generation, expected against actual

Ninety days. The dashed line is the design expectation; the gap between the lines is money.

Soiling loss

Climbs between washes, drops sharply after rain or a clean. The dashed line is the point where a cleaning visit pays for itself.

Performance ratio trend

Against the fleet target.

System specification
Capacity
32.0 kW
System type
On-Grid
Modules
52 x 620W Jinko
Inverter
Fronius Primo-32K (28.8 kW)
Battery
None
Tilt / azimuth
27 deg / 185 deg
Bird mesh
Installed
Tariff
Rs 47 per kWh
Net metering
Renewal due
NM reference
NM-2024-66976
Sanctioned
32 kW
AMC
No contract
Open findings

Unresolved defects on this site.

  • Hotspot detected on string B

    Critical

    Thermal scan shows a cell running 27 degrees above array average. Bypass diode failure suspected.

  • Monitoring app not configured

    Info

    Customer has no visibility of live generation. App setup offered.

Work order history

6 visits

CodeServiceStatusAmount
JOB-2026-0122Same-Day RepairRequestedRs 16.5K
JOB-2026-0143Net Metering AssistanceRequestedRs 35.0K
JOB-2026-0108Hybrid Solar SystemIn progressRs 32
JOB-2026-0136Earthing & Safety InspectionCompletedRs 6.2K
JOB-2026-0008Farm Solar MaintenanceCancelledRs 21.0K
JOB-2026-0049Solar System ExpansionInvoicedRs 3.0L
Inspection reports

Generation figures are modelled against the design estimate for this system.