Thermal Camera Inspection

RPT-2026-002 - performed 11 Aug 2026 by Junaid Khan

Health score

72

Measurements taken

6

1 outside reference

Findings

1

Customer visibility

Shared

Measurements

Each reading against the reference it is judged by.

MeasurementReadingReferenceResult
Open circuit voltage (string A)733 VWithin 5% of designPass
Short circuit current (string A)8.2 AWithin 8% of nameplatePass
Earth electrode resistance2.4 ohmBelow 5 ohmPass
Insulation resistance (DC+ to earth)86 MohmAbove 1 MohmPass
Max module temperature62 CBelow 25 C above ambientPass
Performance ratio on test day72%Baseline 86%Outside reference
Context
Capacity
15.0 kW
Work order
JOB-2026-0042
Technician
Junaid Khan
Recommendation

Bring cleaning forward by one cycle and re-torque the affected strings within 30 days.

Score 72 / 100
Findings

Defects recorded during this inspection.

  • Heavy soiling on lower rows

    MinorResolved

    Dust accumulation reducing output on the two lowest rows more than the rest of the array.