Customer portal

Service history

IV Curve Testing

JOB-2026-0101 - Ahmed Raza

Invoiced

Visit date

22 Feb 2026

Completed

Technician

Tahir Mahmood

Generation gain

+3 kWh/day

Worth about Rs 4,320 a month

Amount

Rs 12,750

What we did

6 of 6 steps completed

  • Visual check of all modules
  • Thermal scan of array
  • String voltage and current logged
  • Earthing continuity verified
  • Inverter fault log downloaded
  • Report drafted and shared
What we found

Anything worth your attention.

Nothing flagged

No defects were recorded on this visit.

Shade Analysis report

RPT-2026-023 - performed 22 Feb 2026

Health score 74
MeasurementReadingReferenceResult
Open circuit voltage (string A)697 VWithin 5% of designPass
Short circuit current (string A)10.8 AWithin 8% of nameplatePass
Earth electrode resistance2 ohmBelow 5 ohmOutside reference
Insulation resistance (DC+ to earth)40 MohmAbove 1 MohmPass
Max module temperature55 CBelow 25 C above ambientOutside reference
Performance ratio on test day83%Baseline 83%Outside reference

Our recommendation

Bring cleaning forward by one cycle and re-torque the affected strings within 30 days.

Timeline
Requested
21 Feb 2026, 2:00 PM
Scheduled
22 Feb 2026, 5:00 PM
Completed
22 Feb 2026, 5:00 PM